Angell Talent II DTP886 Digital R/F Remote-Control Table System
80 kW digital R/F remote-control system for radiography, fluoroscopy, contrast studies and optional tomosynthesis
Product description
The Talent II DTP886 addresses the fragmentation between digital radiography, fluoroscopy and contrast studies in facilities that need a versatile R/F room. Its 80 kW Angell XDRP80 generator, 43×43 cm HCP dynamic detector and DC-DT-4 remote-control table support seamless switching between static and dynamic acquisition. The table supports up to 200 kg, rotates from -15° to +90°, provides tube lateral and vertical movement, and offers one-click standing or lying positioning. The TS-5 workstation adds DICOM 3.0, worklist, video acquisition, bone stitching, image processing and report templates. The wide-range linear TOMO module is optional: it can reach 1 mm layer thickness, 1 mm spacing, up to 300 layers and 1,100 mm coverage, subject to certification and contracted configuration. Final tube, movable console, accessories, software and options must be verified in the quotation.
Key benefits
-
One room covers radiography, fluoroscopy and contrast studies, reducing referrals between separate systems or modalities.
-
Remote operation and exposure-lock switches help keep the operator away from the radiation field and prevent accidental activation within the facility safety protocol.
-
The 200 kg table, -15° to +90° rotation and one-click standing-to-lying positioning adapt the examination to different patients and procedures.
-
The 43×43 cm dynamic detector, up to 30 f/s fluoroscopy and ≤0.8 s spot-film preparation support dynamic and contrast studies with less waiting between acquisitions.
-
DICOM 3.0, worklist, bone stitching, APR and report templates connect acquisition to PACS and help standardize radiology workflow.
Gallery
Specifications
Generación de rayos X
| Parameter | Detail |
|---|---|
| Generador | Angell XDRP80, 80 kW; radiografía 40–150 kV y fluoroscopia 40–125 kV; 0,1–1.000 mAs; AEC y ABS |
| Tubo de rayos X | Siemens SV150/40/80C-100_1; focos 0,6/1,0 mm; hasta 150 kV; capacidad térmica del ánodo 600 kHU |
Tecnología de imagen
| Parameter | Detail |
|---|---|
| Detector dinámico | Angell HCP de panel plano con CsI, área 43×43 cm, matriz estática 3072×3072, 16 bits y resolución espacial estática 3,5 lp/mm |
| Fluoroscopia | Hasta 12 f/s en fluoroscopia pulsada y 30 f/s en fluoroscopia continua; preparación spot-film ≤0,8 s |
Posicionamiento
| Parameter | Detail |
|---|---|
| Mesa de telemando | 2.100×880×715 mm, desplazamiento lateral 250 mm, SID 1,15–1,8 m, rotación -15° a +90° y carga de hasta 200 kg |
| Columna y tubo | Columna ±35°, conjunto del tubo -90°/0°/+90°, brazo con desplazamiento lateral 1.300 mm y vertical 650 mm |
Software e integración
| Parameter | Detail |
|---|---|
| Estación de trabajo | Angell TS-5 con DICOM 3.0, worklist, adquisición estática/dinámica, vídeo, stitching óseo, APR con al menos 1.350 programas y envío a PACS |
Opciones
| Parameter | Detail |
|---|---|
| TOMO opcional | Barrido lineal de gran cobertura: espesor mínimo 1 mm, separación 1 mm, hasta 300 capas y cobertura máxima de 1.100 mm; validar certificación y disponibilidad |
Flujo de trabajo
| Parameter | Detail |
|---|---|
| Consola y seguridad | Consola remota YKT-4, consola móvil YKT-4M opcional, bloqueo de exposición/fluoroscopia, intercomunicación y pedal giratorio 360° |
Clinical applications
- General digital radiography
- Diagnostic and functional fluoroscopy
- Contrast-enhanced examinations
- Pneumoconiosis examination
- Full-spine and lower-limb panoramic imaging
Why institutions choose it
A configurable R/F platform integrating digital radiography, fluoroscopy and contrast studies with remote control and DICOM connectivity.
Frequently asked questions
What is included in the Talent II DTP886?
The reference configuration includes the Angell HCP dynamic detector, XDRP80 generator, SV150/40 tube, collimator, DC-DT-4 table, YKT-4 console, TS-5 workstation, grid and accessories. The movable console and TOMO are optional.
Which examinations can it perform?
Digital radiography, fluoroscopy, gastrointestinal and urological contrast studies, dynamic imaging, bone stitching and other applications defined by the institution's protocol.
What does optional TOMO mean?
The linear tomosynthesis module is not included in every configuration. Layers, coverage, software and certification must be confirmed before purchase.
Does it integrate with PACS?
The sheet specifies DICOM 3.0, worklist and automatic sending; the actual integration depends on the institution's network, PACS and IT configuration.
Are PDF figures final?
The PDF describes a reference configuration. Equipment can be configurable, so tube, detector, console, software and accessories may differ from the generic document; I-ME confirms them in the formal quotation.
Related products
View full category →-
Imaging and Radiology
C-Arm ALC-280 Series
C-Arm with 5kW HF generator and digital detector
View details -
Imaging and Radiology
Ceiling-Mounted DR System
Ceiling-mounted DR X-ray system with automatic tracking
View details -
Imaging and Radiology
Floor-Mounted DR System
Floor-mounted DR X-ray system with wireless detector
View details -
Imaging and Radiology
Mobile DR X-Ray System
Mobile DR X-ray system with 19-inch touch screen
View details
Reviews
No reviews yet. Be the first.
Need more information?
Our sales team can help you choose the right equipment and prepare your quote.
Angell Talent II DTP886 Digital R/F Remote-Control Table System